USER MANUAL MOISTURE ANALYZER ATS 210 and BTS 110D Ver 1 . 2014-08-28
10 USER MANUAL 1. Take all contents out of a package: the moisture analyser and packed separately: the tin pan shield, single use pans, the
USER MANUAL 11 Removing the glass (to clean or remove radiators): 1. Open the moisture analyzer chamber. 2. R
12 USER MANUAL 9. Interfaces The moisture analyser is equipped with RS23C interface to connect a printer or a computer and with PS2 p
USER MANUAL 13 Moisture in substances is an essential quality factor of technical and economical importance. Methods of determining mois
14 USER MANUAL method of homogenizing a sample is mixing. The other method is to draw few samples from different but specific points in a sub
USER MANUAL 15 Attention: Due to temperature sensor localisation, max sample height is 10mm. When substance ply is too thick, surface layers will
16 USER MANUAL Sample values for the most common materials are given in the Appendix, however, be regarded only as preliminary data and it is recomm
USER MANUAL 17 12. Moisture analyzer start After switching-on the moisture analyser proceeds with self-tests and displays company logo. Next the
18 USER MANUAL 13. Drying parameters settings In order to achieve proper density measurement results following parameters should be set: - Dryin
USER MANUAL 19 13.1 Setting drying temperature During setting drying temperature set successively values of individual digits.
2 USER MANUAL Content: 1. Security rules 3 2. Set 3 3. Navigation – fast start 4 4. Moisture analyzer menu diagram 6 5. General
20 USER MANUAL
USER MANUAL 21 13.2 Calculation methods Humidity may be calculated upon the basis of various mathematic formulas, defined in balance – drier as Cal
22 USER MANUAL 13.3 Drier working modes, drying time, sample time During the balance – drier operation sampling of the mass on the
USER MANUAL 23 13.4 Drying profiles Drying profile will be used to optimization of drying process by accommodation a process to phys
24 USER MANUAL gu a on ngs de au 13.5 Moisture analyzer memory The moisture analyser enables to save 20 different drying settings. Saved setting
USER MANUAL 25 ne p = 10s 13.5.2 Loading saved settings In order to call earlier settings saved in memory, You enter the menu and choose option
26 USER MANUAL 13.6 Initial moisture analysis To determine optimal drying parameters for unknown sample, it is recommended to perform
USER MANUAL 27 After measurement a drying graph will show up: m0-m/m0*100% Td=120°C ts= 0:10:00s T = 118.34°C 30% t =0:00:00s m= 1.020
28 USER MANUAL 14. Proper moisture Before measurement carefully prepare the sample (as described in chapter Description of Thermogravimetric Ana
USER MANUAL 29 15. Connecting to a printer or computer – drying report When drying process is finished measurement result can be send
USER MANUAL 3 1. Security rules To avoid electrical shock or damage of the moisture analyzer or connected peripheral devices, it
30 USER MANUAL Using moisture analyzer keyboard user can inscribe signs: 0, 1, 2, 3, 4, 5, 6, 7, 8 and 9 (only digits). A set of characters avai
30 USER MANUAL on = 1sek 16. Moisture analyzer options Moisture analyzer options: - quantity of measurements (Σ) and average f
USER MANUAL 31 - transmission of all successive weight measurements (samples) by serial connection (measurements are printed or saved on computer us
32 USER MANUAL The way of entering control thermometer probe to moisture analyzer drying chamber: 2 100 o C 3 1 1 – control thermometer pro
USER MANUAL 33 Attention: Moisture analyzer internal thermometer correction is made with internal thermometer and control thermometer on the same le
34 USER MANUAL 18. Moisture analyser as a balance The moisture analyser may be also used as a normal balance. To switch between a
USER MANUAL 35 18.2 Auto-zeroing Auto-zeroing function causes that the close to zero indication will be corrected automatically and whe
36 USER MANUAL 18.3 Calibration Calibration with external weight standard should be performed in case indications exceed permissible
USER MANUAL 37 CONFIGURATION 1. Units 2. Auto-zeroing 3. Interface 4. LCD settings 5. Language 6. Time&date 7. Keyboard 8. Defaul
4 USER MANUAL 3. Navigation – fast start After turning on the moisture analyzer, after autotests and tare, moisture analyzer starts initial heati
38 USER MANUAL 19. Maintenance and repairs of small defects 1. A moisture analyser should be kept clean. 2. Take care that no dirt gets between
USER MANUAL 39 Troubleshooting: Display indication Possible cause Remedy Initial heating Td temperature exceeds 105°C, the sensor does n
40 USER MANUAL Declaration of Conformity We: AXIS Spółka z o.o. 80-125 Gdańsk, ul.Kartuska 375B, Poland confirm with all responsibility that mo
USER MANUAL 41 Appendix Drying parameters for different substances (examples) No Substance Initial weight (g) Temperature (°C) Preparation An
42 USER MANUAL 63. Sticks 3-4 75 grind into powder 9 64. 65. Skimmed milk 5 110 mix a sample 66. Skimmed milk powder 5 90 6 67. Fat milk powd
USER MANUAL 5 Moisture analyzer can work in one of two modes, changed by B key: 1) Drying (density measurement) formula evaluation drying insc
6 USER MANUAL 4. Moisture analyzer menu diagram 1. Drying settings 2. Memory settings 3. Drying options 4. Drying raport 5. Configuration 6. Se
USER MANUAL 7 5. General description Moisture analyzers ATS and BTS are designed for fast and precise moisture determination of a sampl
8 USER MANUAL 7. Keys and indicators m0-m/m0*100% Td=105°C ts= 10s T = 32.23°C t =0:00:00s m= 0.000g 0.00 % m0= 0.000g CSD 00:02:00s
USER MANUAL 9 8. Preparation to work During heating, the halogen heaters 1 warm up to very high temperature. When drying chamber is